Method for calculating the number and spacing of cooling mist nozzle installed in cattle barn

cooling mist nozzle installed in cattle barnIf you need to calculate the number and spacing of mist nozzle in your barn, you can refer to the following calculation method:
cooling mist nozzle installed in cattle barn

1. First determine the area of the cattle house. For example, if the area of a cattle barn is 400 square meters.

2. Then determine how many mist nozzle you need per square meter. Generally, you need 0.03-0.05 mist nozzle per square meter. Suppose we choose to require 0.04 mist nozzle per square meter.

3. Calculate the total number of mist nozzle required. Total = Area x Quantity required per square meter = 400 x 0.04 = 16.

4. Finally, adjust according to the actual situation to ensure that the spacing is not more than 3 meters and can cover all cows evenly.

cooling mist nozzle installed in cattle barn

Single layer side jet fan nozzle
Refer to the above for calculating the number of installed and spacing of cooling mist nozzle in cowshed.

In addition, height and density are two very important considerations when installing a cooling nozzle. By choosing the right mounting height and density, you can ensure that the nozzle is able to achieve the full cooling effect, improving the comfort and milk production of the cow.

cooling mist nozzle installed in cattle barn
Installation density of cooling mist nozzle in cowshed
The density of mist nozzle mounted on the top or side walls of cattle sheds should generally be determined by:

1. Size and shape of cowshed:
Larger cattle houses require more mist nozzle to ensure that the spray covers the entire area, while smaller cattle houses require relatively fewer mist nozzle.

2. Flow rate of nozzle:
The higher the nozzle flow, the less dense the installation should be, because fewer mist nozzle can provide enough water.

3. Temperature and humidity:

In hot and humid environments, more mist nozzle are needed to ensure that the temperature and humidity in the cattle house are effectively controlled.

In general, the mounting density of mist nozzle on the top or side walls of the barn can be determined according to the area that each nozzle can cover.
Typically, each nozzle can cover an area of 5-7 square meters, so the mist nozzle should be installed within 5-7 meters of each other. If the ceiling in the barn is high, the nozzle mounting density can be increased slightly.
cooling mist nozzle installed in cattle barn

Cooling mist nozzle installed in cattle barn

Dairy cooling nozzle installation height should pay attention to what side

Hot weather is a common problem in dairy production. Not only can this affect the cow's productivity, but it can also make the cow feel sick or even sick. Therefore, in order to maintain a good production environment and cow health, cooling nozzle is one of the essential equipment.

So, when installing the cooling nozzle, at what height should it be installed? According to our manufacturer's years of experience and technical research, we recommend that the cooling nozzle be installed at a height of about 2.5 meters above the ground.

Why did you choose this height? First of all, at this height the spray is guaranteed to cover the entire dairy farm evenly.

Secondly, this height can minimize the impact of water droplets volatilization and water falling on the ground.

In addition to selecting the appropriate mounting height, we also recommend the adoption of fully automatic control systems to control the use of cooling mist nozzle in dairy farms. Through the intelligent control system, the spray volume and frequency can be automatically adjusted according to the actual temperature, so as to maximize the efficiency and avoid waste.

As a professional manufacturer of cooling mist nozzle, we not only provide high quality products, but also provide perfect after-sales service and technical support. If you have any questions or needs for cooling mist nozzle, please feel free to contact us. We will serve you wholeheartedly.