Shopping mall commercial water-cooled air conditioning mist spray cooling

Shopping commercial air conditioning mist spray cooling
 
Shopping mall commercial water-cooled air conditioning mist spray cooling system, air conditioning mist spray cooling equipment to achieve energy-saving effect
 
After the on-site investigation of the manufacturer and the research of mist cooling experts, it is suggested to add the water mist spray cooling and energy-saving system of the outdoor unit of the air conditioner, in order to reduce the excessive pressure of the air conditioner in summer, the noise impact on the surrounding residents, and achieve energy saving effect.
Air conditioning outdoor unit water mist spray cooling energy saving system, in simple and popular terms, is to connect the air conditioning outdoor unit with a sprinkler device, the use of water cooling, can achieve 15-25% power saving effect.
 
The central air conditioning mist spray cooling system adopts high-pressure micro fog for mist spray cooling, in order to reduce the air conditioning usage overload, prevent the air conditioning host downtime, and also reduce the air conditioning load to achieve energy saving and consumption reduction

Shopping commercial air conditioning mist spray cooling
 
Artificial cooling can make the production reach the best state, in order to avoid the air conditioning host downtime, and affect the use, so as to improve its production efficiency. We achieve this by using a mist spray humidification and cooling system. Water passes through our humidification system and is atomized into extremely fine water particles by atomizing nozzles into the air. These tiny water particles quickly absorb the heat present in the surrounding air, evaporating into water vapor (gas). In the process of evaporation, the heat is gradually reduced, thus achieving a cooling effect. The system is mainly aimed at adjusting the work of the air conditioner for a long time, because the relative humidity in the air is a key factor to determine the cooling, the lower the relative humidity, the faster the fog is absorbed into the air, so more heat can be absorbed to achieve the purpose of cooling. Evaporative refrigeration can be effectively used in a variety of places with cooling needs.
 
Principle: The use d high pressure pump to mist spray water from the atomizing nozzle, forming atomization, fine atomizing particles absorb the heat in the air gasification, so as to achieve cooling effect.

Shopping commercial air conditioning mist spray cooling
 
High pressure mist spray cooling components: high pressure control box, pipeline, atomizing nozzle, joint, solenoid valve, filter, etc.
 
 
 
In practical use, these resins are often converted into other ion modes of operation to meet various needs. For example, strong acidic cationic resin is often treated with NaCl to transform into sodium resin for reuse. When working, the sodium-type resin releases Na+ and Ca2+, Mg2+ and other cation exchange adsorption in the solution to remove these ions. No H+ is released during the reaction, which can avoid the solution pH drop and the resulting side effects (such as sucrose conversion and equipment corrosion, etc.). The resin can be regenerated in salt water (no strong acid required) after running in sodium form. For example, anion resin can be converted into chlorine type for reuse, and Cl- is released when working, and other anions are adsorbed and exchanged, and its regeneration only needs to use salt aqueous solution. Chlorine type resins can also be converted to hydrogen carbonate type (HCO3-) operation. Strong acidic resins and strong basic resins are no longer strongly acidic and alkaline after being converted into sodium and chlorine types, but they still have other typical properties of these resins, such as strong dissociation and a wide pH range.